Accessories
CCA
CCA product transport cases keep
your equipment safe, at any time. During
transport or for safe storage.
Individual for your product.
A combination of products in one case are possible.
More infomation about CCA and some examples are
shown in the Datasheet.
CVP 9222 C
High Impedance Capacitive Voltage Probe
acc. to CISPR 22
EN 55022 C 1.3
Frequency range: 9 kHz - 100 MHz
Options:
Option ACS 110:Charger ACS 110 for CVP 9222, CVP 9222 B and CVP 9222 C.
Option CAL 9222 B: Calibration Adapter for CVP 9222, CVP 9222 B and CVP 9222 C.
CP 9610
The current sensor CP 9610 can measure up to 40 A in a frequency range from DC – 1 MHz. It is galvanically isolated and can withstand a maximum voltage of 210 VPK / VDC. The internal resistance of the conductive path is less than 3 mΩ, providing low power loss. The hall transducer is temperature compensated and allows high accuracy over temperature.
SW 9602
Current Transformer
shielded
0.01 - 200 MHz
Transfer Impedance: 1 Ohm for wires up to 6.5 mm
SW 9603
Current Transformer
shielded
9 kHz - 150 MHz
Transfer Impedance: 1 Ohm for wires up to 14 mm
SW 9605
Current Transformer Clamp
CISPR 22
9 kHz - 80 MHz
Transfer Impedance: 1 Ohm for wires up to 23 mm
SW 9606
Current injection clamp
for RF current injection into harnesses
up to 23 mm diamter
transducer 18 dB
CA 9608
Universal calibration adapter for e.g. the following current clamps:
R&S ESV-Z1, Prodyn, IT-050-1
length and height settable
CISPR 17 Equipment
Transformers
fixtures and adapters to measure filters
ferrites and other passive components.
Detailed product list and data sheets on request.
BD 9501
IEEE-488 Bus-Feed through for flange mounting
(shielded rooms) (other feed throughs on request)
HPF 150 k - High Pass Filter
The HPF is a passive LC-Filter with female N-connectors in shielded metal housing with very steep slope according to CISPR 16-1-1.
The main application is the elimination of noise below 150 kHz for conducted interference voltage measurements. Particular features are high pulse load capacity and dielectric strength.
HPF - High Pass Filter
35 - 1000 MHz
Insertion loss at 27.12 MHz typ. 100 dB
CCC 9224
Capacitive coupling clamp for transients acc. to ISO 7637-3 or DC-10614 B.5.
CCP 9225
Capacitive coupling plate
The main application is to conduct CV-tests (capacitive voltage measurements).
The capacitive coupling plate CCP 9225 complies to the automotive manuafacturer standard MBN 10284-2 2011-04, Annex B.
KU 9608
Coaxial- and line switch for measurement of the attenuation of fluorescent lighting fittings